Needle burner |
inner hole diameter Φ 0.5mm ± 0.1mm, Diameter,≤Φ 0.9mm, |
|
length ≥ 35mm, stainless steel |
Burner angle |
0~45° (adjust flame height) |
Thermocouple |
Ø0.5mm Type K (Ni/Cr - Ni/Al), armored sheath can withstand |
|
temperature-40°C~ 1100°C |
Burning time |
0-999.9 s ± 0.1 s adjustable (usually selected for 30s) |
Hold Burning time |
0-999.9 s ± 0.1 s, automatic recording, manual time-out |
Flame Height |
12mm ± 1mm (with height measurement instruments) |
Flame Gas |
butane gas/Butane gas, min. 95% purity (can use bottled lighter gases) |
Temperature Test Range |
0~1000°C |
Flame Temperature Requirements |
from 100 °C ± 2 °C liters to 700 °C ± 3 °C time in 23.5 seconds ± 1 seconds |
Standard Copper Block |
4mm±0.01mm, weight.0.58g±0.01g before drilling. Cu-ETP |
Test process |
automatic control, independent convulsions |
Chamber |
≥0.5m3 |
Control |
Using single chip microcomputer + touch screen control |
Consult standard |
GB/T5169.10-2006 , IEC60695-11-5:2000,UL746A |
Power Supply |
800VA ,220V, 48-60Hz |
Display panel language |
English(customize available) |