Electrode Materials |
The electrode caput of brass-platinum |
Electrode Distance |
4.0mm±0.1mm,60±5°angle |
Test Voltage |
100~600V adjustable, displayed value: r.m.s |
Test Current |
Current limiting 1A±0.1A adjustable, |
Displayed value |
r.m.s, tolerance of 1.5% |
Electrode Dimensions |
width: 5mm±0.1mm, |
Thickness |
2mm±0.1mm, |
Length |
>12mm, |
End chisel-edge angle |
30°±2°,platinum. |
Electrode Pressure |
1.00N±0.05N |
Dripping Nozzle |
outer diameter: 0.9mm~1.2mm for solution A |
|
0.9mm~3.45mm for solution B |
Dripping Interval |
0-99 seconds (adjustable),the time for 44-55/1cm3(adjustable)drops to fall on the specimen shall be (30±2)min. |
Heigh Drops |
30-40mm±5mm(adjustable) |
Control |
Using single chip microcomputer + touch screen control |
Chamber volume |
>0.5m³, black interior |
Outer Dimensions |
W*D*H=1100mm*700mm*1300mm |
Power Supply |
800VA ,220V, 48-60Hz |
DIN 4102 Part 15 is a significant standard that establishes fire performance requirements for building materials and components. To assess and classify the fire behavior of construction products, specific test apparatus is employed. This article aims to provide an overview of the test apparatus required by the DIN 4102 Part 15 standard, highlighting their importance in ensuring fire safety.