Burner |
Inner diameter Φ9.5mm ± 0.5mm |
Test inclination angle |
45° style beam can move back and forth, adjust the position of the Bunsen burner according to the Specimen thickness; |
Flame height |
20mm ± 2mm to 190mm ± 1mm adjustable |
Flame time |
0-999.9s ± 0.1s adjustable |
Combustion gas |
95% propane gas (usually replaced by liquefied petroleum gas) |
Gas |
high-purity propane gas or liquefied petroleum gas (user-supplied) |
The length of the tested wire and cable |
600±25mm |
Burning torch standard power |
1KW |
Supply voltage |
220V/50Hz |
Gas flow |
0-1L/min |
Air flow |
1.5-15L/min |
Box material |
steel electrostatic spraying |
Dimensions |
length 60 cm wide 45 cm high 156 cm |